Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Flow Meter, Flow Switch, Pressure Sensor, Level Sensor, Level Meter
Establishment:
2012
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, D/P, PayPal, WesternUnion, Small-amountpayment
Main Markets:
North America, Europe, Australia
OEM/ODM Service
Sample Available

Radar Level Meter, Radar Level Transmitter, Radar Transmitter manufacturer / supplier in China, offering Local LCD Display High Frequency Intelligent Radar Water Level Meter, 0.3~30 L/Min Fuel Consumption Micro Flow Meter Used on Marine, 5~1000 Ml/Min Heavy Oil Mazout Micro Oval Gear Flow Sensor and so on.

1
    YRS
General Supplier

China Fuel Flow Sensor

Get Latest Price
Min. Order / Reference FOB Price
1 Piece Contact Supplier
Local Area: Shanghai, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, PayPal, WesternUnion, Small-amountpayment
Measuring Medium: Liquid
Output Signal Type: Analog Type
Material: Metal
Flow Meter Fuel Consumption Flow Meter
A.[Features of Fuel consumption flow meter]
Professional flow meter for fuel consumption
This flow meter just for fuel consumption engine
High Accuracy
This flow meter with 1.0% high accuracy by the rotate piston principle
Display and Output
The fuel consumption flow meter with local mechanical display and pulse output(optional)
Prevent Steal Oil
The fuel consumption flow meter can prevent stealing oil by driver and reduce the cost.
Normal Function
360° Cover , waterproof ,dustproof and connection with GPS.
B.[Parameter]

Production Name Car Boat Fuel Consumption Flow Meter Medium Fuel;Diesel and other oil Display Local Mechanical display Accuracy 1.0% Material Brass cavity Temperature -40~80ºC Pressure 32Bar Output Pulse output

B:Filter
R:Pulse output
OEM:Pulse output but without Display

ModelDisplayFilterFlow range
(L/h)AccuracyOutputPressure
(Mpa)Temperature
(ºC)V4 •-1~1001.0%-32-40~80ºCV4B••1~1001.0%-32-40~80ºCV4OEM--1~1001.0%Pulse32-40~80ºCV4BOEM-•1~1001.0%Pulse32-40~80ºCV4R•-1~1001.0%Pulse32-40~80ºCV4BR••1~1001.0%Pulse32-40~80ºCV8•-4~2001.0%-32-40~80ºCV8B••4~2001.0%-32-40~80ºCV8OEM--4~2001.0%Pulse32-40~80ºCV8BOEM-•4~2001.0%Pulse32-40~80ºCV8R•-4~2001.0%Pulse32-40~80ºCV8BR••4~2001.0%Pulse32-40~80ºC

C.[Function]
Ensure direct measurement accuracte, easy and safe.
It has function same aire elimilator.
Pulsation will disappear when fuel goes through the adjustor.
The pressure in return line will be zero with the adjustor.
The V4 series is suitable for engines less than 200KW;The V8 series is suitable for more than 200KW to 500KW.
They are widely apply to various engines,such as the vechicles;boats;generators,etc.
D.[Installation]
Note:
The operator must have some experience;
The flow meter can not installa near by the exhaust pipe to avoid increase the error
The flow meter shoud be installa the location where low shock
The flow meter should be installa where is easy to read the data
To ensure the pipeline without air to avoid increasing error
Installa the flow meter where lowest of pipeline
Suggest installing the return oil processor
Replace filter regular